Сontrol strategy of shunt active filter for three-phase four-wire power system with multivariate proportional-vector formation of instantaneous source currents

Main Article Content

Myhailo Yuhymovych Artemenko
Larysa Mykolaivna Batrak

Abstract

It is shown that most of the existing control strategies оf shunt active power filters (APF) for three–phase four-wire power system are equivalent to formation of instantaneous source current vector proportional to the referent voltages vector which coincides with the instantaneous vector of the phase voltages or is its part with improved spectral composition. Control system of APF was proposed that realize the multivariate proportional-vector formation of instantaneous source currents. Depending on the application conditions one of the twenty control methods optimal for certain quality characteristics can be selected.

Reference 9, figures 1, tables 2.

Article Details

How to Cite
Artemenko, M. Y., & Batrak, L. M. (2014). Сontrol strategy of shunt active filter for three-phase four-wire power system with multivariate proportional-vector formation of instantaneous source currents. Electronics and Communications, 19(2), 36–44. https://doi.org/10.20535/2312-1807.2014.19.2.142195
Section
Power electronics

References

Fryze S. (1966) "Мoc czynna, bierna i pozorna układu 3–fazowego o odkształconych przebiegach na-pięć fazowych i prądów przewodowych." Мonografii „Wybrane zagadnienia teoretycznych podstaw elektrotechniki”, PWN, Pр.250-256.

Kim H.S., Akagi H. (1997) "The instantaneous power theory based on mapping matrices in three-phase four-wire systems". Proceeding of PCC”97 Conf. Vol. 1. Pр. 361–366.

Kim H.S., Akagi H. (1999) "The instantaneous power theory on the rotating p-q-r reference frames" Proceeding of Int. Power Electronics Conf. PEDS’99. Pp. 422–427.

Kim H.S., Ogasawara S., Akagi H. (1999) "The theory of instantaneous power in three-phase four-wire systems". Proceeding Annual Meеting of IEEC/IAS’99. Pp. 431–439.

Herrera R.S. , Salmeron P. (2007), "Instantaneous Reactive Power Theory: A Reference in the Nonline-ar Loads Compensation“. IEEE Trans. оn Industrial Electronics. Vol. 56, no 6. Pp. 2015–2022.

Herrera R.S., Herrera, Salmeron P. (2007), "Instantaneous reactive power theory: A Comparative Eval-uation of different formulations". IEEE Trans. Power Delivery. vol. 22, no. 1. Pp. 595–604.

Peng F. Z., Lai J. S. (1996), “Generalized instantaneous reactive power theory of three-phase power systems“. IEEE Trans. Instrum. Meas., Vol. 45. No. 1. Pр. 293-297.

Polishchuk S.Y., Artemenko M.Yu., Mykhalskyi V.M. (2013) "Analytical construction of coordinate systems in theory of instantaneous powers of three-phase chains for management by devices of ac-tive filtration". Tekhnichna elektrodynamika. no. 2. pp. 25-35. (Ukr)

Polishchuk S.Y., Artemenko M.Yu., Mykhalskyi V.M., Batrak L. M., Shapoval I. A. (2013)."Shunt active filter control strategy with partial decrease of zero-sequence component in three-phase four-wire sys-tem“. Tekhnichna elektrodynamika. no.3. pp. 12-19. (Ukr).