Virtual phantom of scintigraphic image of the kidney with 99mTc-DMSA

Main Article Content

Николай Александрович Николов
Дмитрий Александрович Супрунюк

Abstract

This work dedicated to problem of phantoms for gamma-camera. It is shown basis points for generating virtual phantom of scintigraphic image of the kidney with 99mTc-DMSA: spatial distribution of preparation in kidney, type and level of noise, shape of kidney. The results of this work allow performing a quantitative evaluation of correctness work of segmentation methods for scintigraphic images. Reference 15, figures 5.

Article Details

How to Cite
Николов, Н. А., & Супрунюк, Д. А. (2015). Virtual phantom of scintigraphic image of the kidney with 99mTc-DMSA. Electronics and Communications, 20(1), 42. https://doi.org/10.20535/2312-1807.2015.20.1.47749
Section
Biomedical devices and systems

References

Biggi A., Dardanelli L., Pomero G., Cussino P., Noello C., Sernia O., Spada A., Camuzzini G. (2001), “Acute renal cortical scintigraphy in children with a first urinary tract infection”. Pediatr. Nephrol. Vol. 16, no 9, pp. 733–738.

Camacho V., Estorch M., Fraga G., Mena E., Fuertes J., Hernández M.A., Flotats A., Carrió I. (2004), “DMSA study performed during febrile urinary tract infection: a predictor of patient outcome?”. Eur. J. Nucl. Med. Mol. Imaging. Vol. 31, no 6, pp. 862–866.

Girotto N., Smokvina A., GrbacIvankovich S., Licul V. (2008), “Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG3”. Nuklearmedizin. Vol. 47, no 1, pp. 43–47.

Guevara D. L., Franken P., DeSadeleer C., Ham H, Piepsz A. (2001), “Inter observer Reproducibility in Reporting on 99mTc–DMSA Scintigraphy for Detection of Late Renal Sequelae”. J. Nucl. Med. Vol. 42, no 4, pp. 564–566.

Heikkinen J. (2004), “New automated physical phantom for renography”. J NuclMed. Vol. 45, no. 7, pp. 495–499.

Heldrich F.J., Barone M.A., Spiegler E. (2000), “UTI: diagnosis and evaluation in symptomatic pediatric patients”. Clin. Pediatr. Vol. 39, no 8, pp. 461–472.

Hitzel A., Liard A., Dacher J. N., Gardin I, Ménard JF, Manrique A, Véra P. (2004), “Quantitative analysis of 99mTc–DMSA during acute pyelonephrit is for prediction of long–term renal scarring”. J. Nucl. Med. Vol. 45, no 2, pp. 285–289.

Hitzel A., Liard A., Vera P., Manrique A., Ménard J.F., Dacher J.N. (2002), “Color and power Doppler sonography versus DMSA scintigraphy in acute pyelonephritis and in prediction of renal scarring”. J. Nucl. Med., Vol. 43, no 1, pp. 27–32.

Hoberman A., Charron M., Hickey R.W., Baskin M., Kearney D., Wald E.R. (2003), “Imaging studies after a first febrile urinary tract infection in young children”. N. Engl. J. Med. Vol. 16, pp. 195–202.

Landgren M., Sjuostrandyz K., Edenbrandt L. (2011), “An Automated System for Analysis of Renal Scintigraphy Images”. SCIA 2011, LNCS. Pp. 489–500. http://www2.maths.lth.se/vision/publdb/reports/pdf/landgren-sjostrand-etal-ssba-12.pdf

Nikolov N.А., Supruniuk D.А., Smetaniuk A.N. (2013), “Stochastic Properties of Nephro scintigraphic Images with 99mTc-DMSA”. Proceedings of the IEEE XXXIII International Scientific Conference “Electronics and Nanotechnology”. Kiev, Ukraine, pp. 246–250.

“Advertising materials of international trading company PTW-Freiburg”. http://www.ptw.de/quality_control_nm.html.

(2002), “Society of Nuclear Medicine Procedure Guideline for Renal Cortical Scintigraphy in Children 2.0. Society of Nuclear medicine procedure guidelines manual 2001”. Pp. 157–160.

Zubovsky G.A., Devishev M.I., Ivanov E.V. (1983), “Radionuclide studies with dynamic phantom”. Medical radiology, Vol. 28, no. 6, pp. 77–81. (Rus)

Nikolov N.A., Kundin V.Yu., Stepanov N.M., Tyholoz S.P (2006), “The computer method of measuring size of the kidneys at analysis of scintigraphic images”. Radio diagnosis, radio therapy, no. 4, pp. 70-74. (Ukr)