Comparison of defibrillation efficacy of different shape and duration bipolar pulses
Main Article Content
Abstract
Based on the analysis of energy-time pulse defibrillation characteristics and use of energy approach to compare the effectiveness of different pulses by cardiac muscle cell membrane excitation threshold, a theoretical study of the comparative effectiveness of defibrillation bipolar pulses of different shapes and durations. Research has shown that a critical factor of the bioobject is no excitation current strength threshold, and the threshold quantity of energy which is released at this current time interval when passing through the object. The obtained results coincided with the simulation results showed that the most effective defibrillation pulses are: Gurvich-Venin pulse and defibrillator FID-02 pulse. The results obtained are confirmed by animal studies and in clinical studies. Reference 8, figures 4.
Article Details
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
References
Venin I.V.,Gurvich N.L., Liberzon A.P., Tabak V.Y., Tsukerman B.M., Sherman A.M. (1973), “Defibrillators DI – 03 and DKI – 01”. Novosti meditsinskogo priborostroeniya. Vol.3, pp. 48-53. (Rus)
Vostrikov V.A., Syirkin A.L., Holin P.V., Razumov K.V. (2003), “Nosocomial cardiac ventricular defibrillation: efficacy of bipolar sinusoidal pulse”. Kardiologiya. Vol.12, pp.18-23. (Rus)
Negovsky V.A., Smerdov A.A., Tabak V.Y., Venin I.V. (1980), “Criteria of efficiency and safety of the defibrillating impulse”. Resuscitation. Vol.8, pp. 53-67.
Vostrikov V.A. (2012), “Efficacy and safety of electrical defibrillation of the heart ventricles: experiment and clinic”. Obschaya reanimatologiya. Vol.8, pp. 79-87. (Rus)
Vostrikov V.A., Gorbunov B.B. (2004), “Efficacy and safety of electrical defibrillation of the heart ventricles: experiment and clinic”. Klinicheskaya anesteziologiya i reanimatologiya. pp.16–18. (Rus)
Vostrikov V.A., Gorbunov B.B., Gusev A.I. (2014), “Computer modeling of the impact of the first phases of defibrillation pulse bipolar membrane forms on cardiomyocyte”. Obschaya reanimatologiya. Vol.1, pp.25-28. (Rus)
Harkevich A.A. (1973), “Spectra and analysis”. Izbrannyie trudyi. Vol.2, P. 566. (Rus)
Smerdova T.A. (2014), “Energy-time of defibrillation waveforms”. Modern problems of radio engineering, telecommunications and computer science, pp. 716-718.