The power factor and efficiency of the three-phase power systems with linear asymmetric load
Main Article Content
Abstract
This work analyses the influence of the asymmetry of the three-phase circuit linear load and the power loss in the neutral wire of four-wire power supply system on the power factor and the efficiency. The new formula of the approximate dependence of the three-phase system from the power factor, which can be used for the valuation of the improvement of the energy characteristics of the electrical power system provided by the reactive compensator or the active filter. The identity of the taken out formulas is checked by the comparison of the exact and the approximate dependence of efficiency of the supply system from the quantity of resistance loss for the uniform of unbalanced load with different ratio of resistances.
Article Details
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
References
Artemenko M. Yu., Batrak L. M., Domaskina N.I. (2015), Apparent power of three-phase four-wire system in sinusoidal asymmetric mode and energy effectiveness of shunt active filters. Proceedings of IEEE XXXV International Scientific Conference “Electronics and nanotechnology”, pp. 469-474.
Czarnecki L.S., Haley P.M. (2014), Unbalanced Power in Four-Wire Systems and Its Reactive Compensation. IEEE Trans. Power Delivery, Vol.30, No.1, pp. 53-63.
Leszek S. Czarnecki (2008), Currents’ Physical Components (CPC) concept: a fundamental of Power Theory. Przegląd Elektrotechniczny, No.6, pp. 28-37.
Sirotin Iu. (2011), Fryze’s compensator and Fortescue transformation. Przeglad Elektrotechniczny (Electrical Review), Vol.1, pp. 101-106.
Artemenko M. Yu. (2014), Full power of three-phase power supply system in the non-sinusoidal mode and the energy efficiency of parallel active filtration. Electronics and Communication, No.6, pp. 38-47. (Ukr)
Zhemerov G.G., Tuhai D.V. (2014), Energy and power in power supply systems with semiconductor converters and energy storage. Elektrotekhnika i Elektromekhanika, No.1, pp. 45-57. (Rus)
Maevskyi O.A. (1978), The energy performance of valve converters. (Energy, Moscow). (Rus)